There is no universal evaporation rate formula. Instead, different equations are used depending on the context—such as meteorology, engineering, or hydrology—and the data available. The most accurate methods combine energy balance and vapor transfer principles.
Understanding evaporation rate units
Evaporation rate is reported in two main ways: mass flux and depth rate. Mass flux measures kilograms of water evaporated per square meter per second (kg/m²/s). This is common in engineering. Depth rate measures how many millimeters of water depth are lost per day (mm/day), which is standard in hydrology and weather reporting.
To convert between them, use the density of water (about 998 kg/m³ at 20°C):
Depth rate (m/s) = Mass flux (kg/m²/s) / 998
For example, 0.0115 kg/m²/s equals about 1 mm/day. Unit errors, like mixing grams and kilograms or meters and millimeters, are common, so check carefully.
Key thermodynamic factors
Latent heat of vaporization
When water evaporates, it absorbs energy from its surroundings. This is the latent heat of vaporization (Lv). For water at 20°C, Lv is about 2.45 million joules per kilogram (2.45 MJ/kg). This value decreases slightly as temperature increases.
Because evaporation removes heat, it cools the surface. This is why sweating cools your skin. If no heat is added, the surface temperature drops.
Vapor pressure and humidity
At the water surface, air becomes saturated with water vapor. The maximum vapor pressure at a given temperature is called saturation vapor pressure (es). It increases with temperature. A common approximation is the Magnus–Tetens formula:
es(T) = 0.6108 × exp(17.27 × T / (T + 237.3))
where T is in °C and es is in kPa. At 20°C, es is about 2.34 kPa.
The actual vapor pressure in the air (ea) depends on relative humidity (RH): ea = RH × es(air temperature). The difference between es at the surface and ea in the air is the vapor pressure deficit (VPD), which drives evaporation.
Two main modeling approaches
Aerodynamic (mass transfer) method
This method calculates evaporation based on how quickly vapor moves from the surface into the air. Wind and turbulence help carry vapor away. The basic form is:
Evaporation = f(wind speed) × (es(surface) – ea)
The function f(wind speed) increases with wind speed. Without direct surface temperature, this method needs assumptions about the surface–air temperature difference.
Energy balance method
Evaporation cannot exceed the energy available. The surface energy balance equation is:
Net radiation – Ground heat flux – Sensible heat flux = Latent heat flux
In symbols: Rn – G – H = LvE
Here, Rn is incoming minus outgoing radiation, G is heat stored below the surface, H is heat transferred to the air, and LvE is the energy used in evaporation. This method sets a physical upper limit: even dry air cannot cause evaporation if there's no energy to power it.
Combining both: the Penman equation
In 1948, Howard Penman combined the aerodynamic and energy balance methods to estimate evaporation without needing surface temperature. The Penman equation uses air temperature, humidity, wind speed, and radiation to calculate evaporation from open water or wet surfaces.
It uses the slope of the saturation vapor pressure curve (Δ) and psychrometric constant (γ) to weight the contributions of energy and mass transfer. It’s widely used in agriculture, hydrology, and climate studies.
While the full equation is complex, it’s implemented in many software tools and weather stations to estimate reference evapotranspiration (ETo).